Product Details:
|
Sine Force Peak: | 2400kg.f(10 KN) | Random Force: | 2200kg.f(10 KN) |
---|---|---|---|
Shock Force: | 4400kg.f(44 KN) | Frequency Range: | 2-3000 Hz |
Max Displacement: | 51 Mm | Power Supply: | 3-phase AC 380V / 50Hz |
Power: | AC 380V 50HZ Or Customized | Usage: | Simulation Transport Vibration Test Machine |
Warranty: | 12 Months | ||
High Light: | vibration test table,vibration lab equipment,1000kgf Vibration Test Equipment |
A Vibration Test System consists of four major components
Item | Configuration | Qty. |
1) | Vibration shaker | |
A20S34 shaker (included Pneumatic Centering Controller) | 1 set | |
B752S blower (included silencer and Duct ) | 1 set | |
Head Expander VT80CM | 1 set | |
Horizontal Slip table HG80M | 1 set | |
2) | Power Amplifier | |
LA20K Power amplifier(including Field power supply) | 1 set | |
3) |
Vibration Controller-Vcs-02 (Including Hardware and Control Functions Program software CDS |
|
Accelerometer (Including Length 7m low noise BNC-M5 cable) | 2 set | |
Computer(Including keyboard, mouse and monitor) | 0 set | |
4) |
Documentation Operation Manual, Packing List |
1 set |
5) | Accessories | |
Maintenance Tools | 1 set | |
Standard Spare Parts | 1 set |
Shaker Specifications | |
Peak Sine (Pk) | 2400Kg.f peak (24KN) |
Random (RMS) | 2200Kg.f rms (22KN) @ISO5344 |
Shock (Pk) | 4400Kg.f peak (44KN) @6ms |
Usable Frequency | DC~3000Hz |
Maximum Displacement (p-p) | 51mm (2inch) |
Max. velocity | 2m/s |
Max. acceleration | Sine:100g (980 m/s2);Random: 60g (588 m/s2) |
Vertical Load Support | 400 kg |
Body Suspension Natural Frequency (Thrust Axis) |
Less than 2.5 Hz |
Armature Diameter | Ф340 mm |
Armature Weight | About 24kg |
Fundamental Resonance Frequency (Bare table) |
2,600 Hz (nom.) +/- 5% |
Load Attachment Points (Standard) |
21stainless steel M10 Inserts |
Stray Flux Density | <10gauss |
Allowable partial force | 500.N.M |
Shaker dimensions | 1190mmL×860mmD×1060mmH |
Power Amplifier Specifications LA20K | |
Rated Output Capacity | 22KVA |
Signal to Noise Ratio | Greater than 65 dB |
Amplifier Efficiency | Greater than 90% |
Amplifier Overall Dimensions | 650mmL×920mmD×1780mmH |
Weight of Amplifier | 470Kg |
Interlock Protection | ●Input Over/Under Voltage ●Logic Fault ●Output Over Voltage/Current ●Control Power ●External ●Shaker Oil Pressure ●Module O/T ●Shaker Temp ●Shaker Travel |
Shaker controller Specifications VCS-02 | |
Hardware |
2 Analog Input Channels, 1 Drive Channel 102.4 kHz Sampling Rate, 40kHz Frequency Range, >120dB Dynamic range ,24-bit ADC/DAC,Centralized 32-bit floating DSP processing and low-noise design ,> 90 dB Random control dynamic range , Windows O/S GUI and Ethernet connectivity, graphic interface.-20~60℃ Working Temperature Fanless Structure to Reduce the Background Noise. |
Control Functions |
●Base Random,●Swept Sine,●Classic Shock, ●Resonance Search and Tracked Dwell(optional) |
PC Configuration: | ● PC(i3-3.6GHz CPU 8GB 1TB 1000Mbps Ethernet port.and 4 USB port / Microsoft Windows 10 OS) |
Control Accelerometers |
●Mode: LTE-B03A00 High sensitivity Charge acceleromteter ,C M5 coaxial plug to BNC plug low noise cable ,1—8kHz ,20mV/g ,M5 side Conn,Ground isolation,-40℃ to 160℃ |
Head Expander Specifications VT80CM | |
Material | Magnesium alloy |
Dimension | 800mmX800mm |
Effective Mass in kg | 50KG |
Usable Frequency | Random: 2000Hz; Sine: 1300Hz |
Horizontal Slip Table HG80M | |
Material | Magnesium alloy |
Dimension | 800mmX800mm |
Effective Mass in kg | 70KG |
Usable Frequency | 2000Hz |
Blower Specification B752S | |
Blower Power | 7.5kW (10 HP) |
Air Flow/Pressure: | 1.35 m3/s @0.008 Mpa |
Blower dimensions | 950mmx720mmX1460mm |
Weight of Blower | 190kg |
System Environmental Requirement | |
Power Requirement | 380VAC, 50 Hz, 3Ph, 44 kVA |
Operating Room Temperature | 0 to 40 degree C |
System Continuous Duty | not less than 8 hours at the full ratings |
Humidity | 0 to 85%, non condensing |
Compressed Air Requirement | 0.7 Mpa |
Test requirements and model selection guide
To choose a suitable vibration test system, the most important thing is to know the exciting force required to perform the vibration test. To evaluate and calculate the exciting force, the following test specifications should be known:
The specimen fixation is selected based on the upper limit of test frequency and specimen size, either vertical expansion platform or horizontal slip table. Specimen mass is needed to evaluate the required exciting force for vibration tests.
When evaluating the exciting force needed for vibration test, you can choose a temporary armature mass (according to the model of EV series)
Vibration Testing Equipment Pictures:
Contact Person: Mr. Labtone
Fax: 86-769-85370093